Applied Mathematics and Nonlinear Sciences
Journal license

Journal

Applied Mathematics and Nonlinear Sciences


Volume
& Issue

Volume 9, Issue 1


Published
on

July 20, 2024


Pages


DOI

Article

Analysis and Research on A High-precision Remote Transformer Calibration Device Considering The Influence of Excitation Current

Check for updates


Authors

Jiliang Fu Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.
, Quan Wang Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.
, Cong Qi Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.
, Qiancheng Zhao Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.
, Xueqin Yu Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.
and Xin Qi Affiliation:
China Electric Power Research Institute Co., Ltd, Wuhan 430074, Hubei, China.


Abstract

With the popularization of digital transformer substations, it is of great research significance to study the upgrade of electronic transformer calibration devices, especially in the scene of small signals and high precision. In this paper, a compensation correction method is proposed to obtain more accurate primary side current parameters of the tuning device. By establishing the J-A magnetic characteristic model of the CT, the relationship between the magnetic characteristics of the CT and the corresponding terminal voltage is analyzed, and the relationship model between the terminal voltage and the corresponding excitation current is established. The model is used as the correction value in the feedback loop of the current measurement of the integral inspection device, to obtain the accurate primary side current. This method is applied to an electronic transformer calibrator inspection device system based on the Beidou system, which improves the data measurement accuracy of the device sensor and ensures that the measurement data accuracy reaches 0.1S.


Keywords

Electronic transformer calibrator, Excitation current, POS intelligent algorithm, Beidou system, Multi-channel sampling, 78A97


Citation

Fu, J., Wang, Q., Qi, C., Zhao, Q., Yu, X., & Qi, X. (2024). Analysis and research on a high-precision remote transformer calibration device considering the influence of excitation current. Applied Mathematics and Nonlinear Sciences, 9(1). https://doi.org/10.2478/amns-2024-1850

Published by: Engineering Journals

Engineering Journals Logo