Applied Mathematics and Nonlinear Sciences
Journal license

Journal

Applied Mathematics and Nonlinear Sciences


Volume
& Issue

Volume 9, Issue 1


Published
on

June 3, 2024


Pages


DOI

Article

Construction and Optimization of Dynamic Assessment Indicators for Distribution Grid Carrying Capacity with High Proportion of Distributed Resource Connections

Check for updates


Authors

Zhongqiang Zhou Affiliation:
Department of Automation, Dispatching & Control Center of Guizhou Power Grid, Guiyang, Guizhou, 550000, China.
, Yuan Wen Affiliation:
Power Dispatching & Control Center, Kaili Power Supply Bureau of Guizhou Power Grid, Kaili, Guizhou, 556000, China.
, Dan Jiang Affiliation:
Power Dispatching & Control Center, Tongren Power Supply Bureau of Guizhou Power Grid, Tongren, Guizhou, 554300, China.
, Ruifeng Deng Affiliation:
Power Dispatching & Control Center, Xingyi Power Supply Bureau of Guizhou Power Grid, Xingyi, Guizhou, 562400, China.
, Jianwei Ma Affiliation:
Department of Automation, Dispatching & Control Center of Guizhou Power Grid, Guiyang, Guizhou, 550000, China.
and Jingrong Meng Affiliation:
Shanghai Jiao Tong University Sichuan Research Institute, Chengdu, Sichuan, 610000, China.


Abstract

In this study, we evaluate the enhanced carrying capacity of the modified IEEE 33-node distribution system, which incorporates a high percentage of distributed resource (DR) integration, utilizing the whale optimization algorithm. The evaluation employs a fuzzy comprehensive evaluation (FCE) method, wherein we construct FCE indices for factors influencing the distribution network’s carrying capacity. These indices involve calculating weight coefficients and establishing an affiliation function, culminating in the output of the final fuzzy evaluation result vector. The analysis identifies three nodes—11, 18, and 31—within the IEEE 33-node system for decentralized DR installation. Based on initial scenario data, the maximum carrying capacity of the distribution network is determined to be 40.68 MW. The analysis further reveals that the utilization rate of distributed resources reaches 100% at specific times, specifically at 2:00 AM and 6:00 AM. During the 3:00 to 5:00 AM interval, both the system voltage excursion index and the composite score for distribution network losses are calculated to be low. These findings suggest the feasibility of integrating a single regional distribution network with other energy networks, thereby facilitating multi-regional resource interconnection and enhancing the flexibility of system operations. This approach offers significant implications for improving the robustness and efficiency of electrical distribution systems.


Keywords

Whale optimization algorithm, Fuzzy comprehensive evaluation, Distributed resources, Carrying capacity, 97P10


Citation

Zhou, Z., Wen, Y., Jiang, D., Deng, R., Ma, J., & Meng, J. (2024). Construction and optimization of dynamic assessment indicators for distribution grid carrying capacity with high proportion of distributed resource connections. Applied Mathematics and Nonlinear Sciences, 9(1). https://doi.org/10.2478/amns-2024-1352

Published by: Engineering Journals

Engineering Journals Logo